19V 400W / MDS-400AUS19 B

Highlights & Features

  • Compliant to IEC 60601-1 3rd edition

  • IT and medical safety approvals

  • Low earth leakage current (<0.1mA)

  • Overload, over voltage, over temperature and short circuit protections

  • Risk management report available


Dimensions (W x L x H): 97 x 198 x 41.5 mm
Unit Weight: 0.91 kg

Output

  • Nominal Output Voltage19V

  • Output Current21.1A

  • Output Power400W

  • Line Regulation±0.5%

  • Hold-up Time12ms @ 115Vac

  • Ripple & Noise104mV pk-pk @ Full load (typ.)

Input

  • Nominal Input Voltage100-240Vac

  • Input Voltage Range90-264 Vac

  • Nominal Input Frequency50-60Hz

  • Input Frequency Range47-63Hz

  • Input Current5.5A @ 90Vac,
    2.7A @ 264Vac

  • Input Power (Standby Mode)1.2W

  • Efficiency at 100% load91.4% (typ.)

  • Max. Inrush Current60A @ 115Vac,
    60A @ 230Vac (typ.)

  • Leakage Current0.1mA @ 240Vac Normal Condition,
    0.3mA @ 264Vac Single Fault Condition

  • Nominal Current5.5A at 90Vac -2.7A at 264Vac

Mechanical

  • Case Chassis / Case CoverAL1100F(+Anode)

  • Dimensions (W x L x H)97 x 198 x 41.5 mm

  • Unit Weight0.91 kg

  • Input TerminalDECA T33-BM1103A301

  • Output TerminalDECA T33-BM1104A301

ENVIRONMENT / PROTECTIONS / RELIABILITY / SAFETY / EMC

  • Operating Ambient Temperature-10°C to +70°C

  • Storage Ambient Temperature-40°C to +85°C

  • Power De-rating-10°C to +50°C 100% load
    +50°C to +70°C de-rate power by 2.5% / °C

  • Operating Humidity10-95% RH (Non-Condensing)

  • Shock Test (Non-Operating)50G 11ms, 3 shocks for each direction

  • Vibration Test (Non-Operating)5-500Hz, 2.09Grms, 20minutes for each three axis

  • Overvoltage Protection150%, Latch Mode

  • Overload / Overcurrent Protection150% of rated load current, Hiccup Mode, (Non-Latching, Auto-Recovery)

  • Over Temperature ProtectionHiccup Mode, (Non-Latching, Auto-Recovery)

  • Short Circuit ProtectionHiccup Mode, (Non-Latching, Auto-Recovery)

  • Protection Against ShockClass I with PE connection

  • MTBF2075 kHrs based on Telcordia SR-332

  • EmissionsEN55011, EN55022, FCC Title 47: Class B

  • Voltage Fluctuation and FlickerEN61000-3-3

  • ITEIEC60950-1 (Ed.2,2005), GB4943.1-2011, GB9254-2008, GB17625.1-2003

  • CEMDD Directive 93/42/EEC

  • EFTEN61000-4-4, Level 3 (2kV) Perf Criteria A

  • SurgeEN61000-4-5, Level 3 Criteria A Common Mode: 2kV Differential Mode: 1kV

  • Conducted ImmunityEN61000-4-6, Level 2 Criteria A 150kHz-80MHz, 3Vrms

  • Magnetic FieldEN61000-4-8, Criteria A Magnetic field strength 3A/Meter

  • Voltage DipsConform to EN61000-4-11, 30% 10ms Criteria A,60% 100ms and 100% 5000ms Criteria B