Delta台达集团 台达电源PMT系列平板式12V直流电源供应器PMT-12V35W1AA
区域总代
正品保证
快速发货
  • 产品详情
  • 产品参数
  • 产品评论

Panel Mount

PMT 系列

PMT-12V35W1AA

输出电压

12V

输出功率

35W

输出电流

2.92A

输入电压范围

90-264Vac

尺寸 (L x W x H)

98 x 98 x 38 mm

3.86” x 3.86” x 1.50”

重量

0.22 kg (0.49 lb)

亮点与特色
  • 全球通用交流输入电压范围

  • 输入电压全范围功率不降级

  • MTBF > 700,000 hrs Telcordia SR-332

  • 短路 / 过压 / 过负载 / 过温保护

  • 万能连接器选项(标准型端子台,朝前型端子台,线束型连接器)

ModelDescription
PMT-12V35W1AGEnclosed, front face connector
PMT-12V35W1AHEnclosed, harness connector
PMT-12V35W1AABOpen Frame, terminal block, conformal coating

 PMT

Highlights & Features

Universal AC input voltage range

Power will not de-rate from input voltage 90 Vac to 264 Vac

High MTBF > 700,000 hrs per Telcordia SR-332

Short Circuit / Overvoltage / Overload / Over Temperature Protections

Versatile connector options (Terminal Block, Front Face, Harness)


Safety Standards

CB Certified for worldwide use


Model Number:        PMT-12V35W1A

Unit Weight:        0.22 kg (0.49 lb)

Dimensions (L x W x H):    98 x 98 x 38 mm

                                           (3.86 x 3.86 x 1.50 inch)


General Description

The new PMT series of panel mount power supplies is the latest offering from one of the world’s largest power supply manufacturers and solution providers - Delta. The first range of PMT products will offer a nominal output voltage of 12V with a wide operating temperature range from -10°C to +70°C and can withstand shock and vibration requirements (in accordance to IEC 60068-2-27 and IEC 60068-2-6 respectively). In addition to features like overvoltage and overload protections, Delta’s PMT series of panel mount power supplies is unlike many other brands in the same price level. The PMT series is designed for cost competitive markets without compromising the quality of the components and product specifications. The series of products has an expected life time of 10 years and will have no output power de-rating from 90 Vac to 264 Vac. This versatile series has three different connector options (Terminal Block, Front Face and Harness) and can also be converted into L Frame (PML) or Open Frame (PMB) type of power supplies to satisfy different application needs.


Model Information

PMT Panel Mount Power Supply



Model Number
Input Voltage Range
Rated Output Voltage
Rated Output Current
PMT-12V35W1A
90-264 Vac
12 Vdc
2.92 A



Model Numbering









CC Code**
PM
12V
35W
1
A
Panel Mount
Product Type
T – Enclosed
L – L Frame*B – Open
      Frame*
Output Voltage
Output Power
Single Phase
No PFC
Connector Type
A – Terminal Block
G – Front Face*H – Harness*
Blank – Without
connector cover
A – With connector
cover
B – With conformal
coating


*Options           **For Enclosed type with Terminal Block

Specifications

Input Ratings / Characteristics



Nominal Input Voltage
100-240 Vac

Input Voltage Range
90-264 Vac

Nominal Input Frequency
50-60 Hz

Input Frequency Range
47-63 Hz

Input Current
< 0.75 A @ 115 Vac, < 0.50 A @ 230 Vac

Efficiency at 100% Load
> 84.0% @ 115 Vac & 23 0Vac

Max Power Dissipation
0% load
0.29 W typ. @ 230 Vac

100% load
6.11 W typ. @ 230 Vac
Max Inrush Current (Cold Start)
< 30 A @ 115 Vac, < 60 A @ 230 Vac

Leakage Current
< 1 mA @ 240 Vac




Output Ratings / Characteristics*



Nominal Output Voltage
12 Vdc
Factory Set Point Tolerance
12 Vdc ± 2%
Output Voltage Adjustment Range
11-14 Vdc
Output Current
2.92 A (35 W max.)
Output Power
35 W
Line Regulation
< 0.5% typ. (@ 90-264 Vac input, 100% load)
Load Regulation
< 1% typ. (@ 90-264 Vac input, 0-100% load)
PARD** (20MHz)
< 100 mVpp @ 0°C to 50°C < 150 mVpp @ -10°C to 0°C
Rise Time
< 30 ms @ nominal input (100% load)
Start-up Time
< 2500 ms @ nominal input (100% load)
Hold-up Time
> 16.7 ms @ 115 Vac (100% load)


Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ 0-100% load
(Slew Rate: 0.1 A/μS, 50% duty cycle @ 5Hz)
Start-up with Capacitive Loads
8,000 µF Max


*For power de-rating from 50°C to 70°C, see power de-rating on page 3.

**PARD is measured with an AC coupling mode, 5cm wires, and in parallel with 0.1µF ceramic capacitor & 47µF electrolytic capacitor.



Mechanical



Case Chassis / Cover

Aluminium / SGCC
Dimensions (L x W x H)

98 x 98 x 38 mm (3.86 x 3.86 x 1.50 inch)
Unit Weight

0.22 kg (0.49 lb)
Indicator

Green LED (DC OK)
Cooling System

Convection
Terminal
PM-12V35W1AA
M3.5 x 5 Pins (Rated 300 V / 15 A)

PM-12V35W1AG
M3.5 x 5 Pins (Rated 300 V / 20 A)

PM-12V35W1AH
I/P (JST): B3P5-VH(LF)(SN)O/P (JST): B2P3-VH(LF)(SN)
Wire
PM-12V35W1AA
AWG 22-12

PM-12V35W1AG
AWG 22-12

PM-12V35W1AH
AWG 22-18 (For the recommended Mating Connector and Terminal, please refer to the Table on Page 12)
Noise (1 Meter from power supply)

Sound Pressure Level (SPL) < 25 dBA




Environment



Surrounding Air Temperature
Operating
-10°C to +70°C

Storage
-25°C to +85°C
Power De-rating

> 50°C de-rate power by 2.5% / °C
Operating Humidity

5 to 95% RH (Non-Condensing)
Operating Altitude

0 to 5,000 Meters (16,400 ft.)
Shock Test
Non-Operating
IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions
Vibration
Non-Operating
IEC 60068-2-6, Random: 5Hz to 500Hz (2.09 Grms);
20 min per axis for all X, Y, Z direction
Over Voltage Category

II
Pollution Degree

2




Protections



Overvoltage
16 V, +10% / -5%, SELV Output, Hiccup Mode, Non-Latching (Auto-Recovery)
Overload / Overcurrent
> 120% of rated load current, Hiccup Mode,Non-Latching (Auto-Recovery)
Over Temperature
Non-Latching (Auto-Recovery)
Short Circuit
Hiccup Mode, Non-Latching
(Auto-Recovery when the fault is removed)
Internal Fuse at L pin
T3.15 AH
Degree of Protection
IPX0
Protection Against Shock
Class I with PE* connection


*PE: Primary Earth




Reliability Data



MTBF

> 700,000 hrs as per Telcordia SR-332I/P: 100Vac, O/P: 100% Load, Ta: 35°C)
Expected Cap Life Time

10 years (115 Vac & 230 Vac, 50% load @ 40°C)




Safety Standards / Directives



Safety Entry Low Voltage

SELV
Electrical Safety
TUV Bauart
UL/cUL recognized


CB scheme
BIS
CCC


EN 60950-1, EN 62368-1
UL
60950-1 and CSA C22.2 No. 60950-1 (File No. E131881)
UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E131881)IEC 60950-1, IEC 62368-1
IS 13252 (Part 1) (for PMT-12V35W1AA)
GB 4943.1 (for PMT-12V35W1AA)
CE

In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
UKCA

In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
Galvanic Isolation
Input to Output
3.0 KVac

Input to Ground
1.5 KVac

Output to Ground
0.5 KVac




EMC  



Emissions (CE & RE)

CISPR 32, EN/BS EN 55032, FCC Title 47: Class B
Immunity

EN/BS EN 55024
Electrostatic Discharge
IEC 61000-4-2
Level 4 Criteria A1)   Air Discharge: 15 kVContact Discharge: 8 kV
Radiated Field
IEC 61000-4-3
Level 3 Criteria A1)   80 MHz-1 GHz, 10 V/M with 1 kHz tone / 80% modulation
Electrical Fast Transient / Burst
IEC 61000-4-4
Level 3 Criteria A1)   2 kV
Surge
IEC 61000-4-5
Level 3 Criteria A1) Common Mode2): 2 kVDifferential Mode3): 1 kV
Conducted
IEC 61000-4-6
Level 3 Criteria A1)   150 kHz-80 MHz, 10 Vrms
Power Frequency Magnetic Fields
IEC 61000-4-8
Criteria A1)   10 A / Meter
Voltage Dips and Interruptions
IEC 61000-4-11
100% dip; 1 cycle (20 ms); Self Recoverable
Low Energy Pulse Test (Ring Wave)
IEC 61000-4-12
Level 3 Criteria A1)   Common Mode2): 2 kVDifferential Mode3): 1 kV


1) Criteria A: Normal performance within the specification limits

2) Asymmetrical: Common mode (Line to earth)

3) Symmetrical: Differential mode (Line to line)



Block Diagram




Device Descriptions


PMT-12V35W1AA: Terminal Block
PMT-12V35W1AG: Front Face
PMT-12V35W1AH: Harness



Input & Output terminal block connector

DC voltage adjustment potentiometer

DC OK control LED (Green)


Dimensions

PMT-12V35W1AA: Terminal Block

L x W x H: 98 x 98 x 38 mm (3.86 x 3.86 x 1.50 inch)

PMT-12V35W1AG: Front Face

L x W x H: 98 x 98 x 38 mm (3.86 x 3.86 x 1.50 inch)

PMT-12V35W1AH: Harness

L x W x H: 98 x 98 x 38 mm (3.86 x 3.86 x 1.50 inch)


PML-12V35W1AA: Terminal Block

L x W x H: 97.5 x 98 x 37.5 mm (3.84 x 3.86 x 1.48 inch)

PML-12V35W1AG: Front Face

L x W x H: 97.5 x 98 x 37.5 mm (3.8.4 x 3.86 x 1.48 inch)


PML-12V35W1AH: Harness

L x W x H: 97.5 x 98 x 37.5 mm (3.84 x 3.86 x 1.48 inch)

PMB-12V35W1AA: Terminal Block

L x W x H: 91 x 94.3 x 30.6 mm (3.58 x 3.71 x 1.20 inch)


PMB-12V35W1AG: Front Face

L x W x H: 91 x 94.3 x 30.6 mm (3.58 x 3.71 x 1.20 inch)

PMB-12V35W1AH: Harness

L x W x H: 91 x 94.3 x 30.6 mm (3.58 x 3.71 x 1.20 inch)

Engineering Data

Output Load De-rating VS Surrounding Air Temperature








Output Load De-rating VS Input Voltage

   



Assembly & Installation

  Mounting holes for power supply (device). The power supply shall be mounted on minimum 2 mounting holes using M3 screw minimum 5 mm (0.20 inch) length.

    This surface belongs to customer’s end system or panel where the power supply is mounted.

    Connector



Side Mounting (Vertical)
Base Mounting (Vertical)
Side Mounting (Horizontal)
Fig. 2    Recommended Mounting Orientations





Fig. 3    Assembly Reference



Ensure the mounted device is kept at ≥ 4 mm (0.16 inch) safety distance at all sides from other components and equipments. In addition, to ensure sufficient convection cooling, always maintain a distance of ≥ 20 mm (0.79 inch) from ventilated surfaces while the device is in operation.


PM-12V35W1AA / PM-12V35W1AG: Use flexible cable (stranded or solid) of AWG No. 22-12. User should calculate and select the suitable wire specification (type/quantity/diameter) according to actual output current. The torque at the Connector shall not exceed 13 Kgf.cm (11.23 lbf.in). The insulation stripping length should not exceed 0.275” or 7 mm (Refer to Fig. 3).

PM-12V35W1AH: Please refer the table below for the recommended mating connector, terminal and AWG wire size.




Header (Board Mounting)
Mating Connector
Terminal
AWG
Input (JST)
B3P5-VH(LF)(SN)
VHR-5N
SVH-21T-P1.1
22-18
Output (JST)
B2P3-VH(LF)(SN)
VHR-3N





Fig. 4    Mounting Screw



Safety Instructions

If user’s mounting orientation is not according to the recommended mounting orientations, please consult Delta for further information.

L frame (PML) and Open frame (PMB) options are to be manufactured by Delta and not to be reconfigured by users from the standard enclosed configuration.

The device is not recommended to be placed on low thermal conductive surface. For example, plastics.

The enclosure of the device can become very hot depending on the ambient temperature and load of the power supply. Do not touch the device while it is in operation or immediately after power is turned OFF. Risk of burning!

Do not touch the terminals while power is being supplied. Risk of electric shock.

Prevent any foreign metal, particles or conductors from entering the device through the openings during installation.It may cause electric shock, safety hazard, fire and/or product failure.

The power supply must be mounted by metal screws onto a grounded metal surface. It is highly recommended that the Earth terminal on the connector be connected to the grounded surface.

Warning (For Standard Terminal Block and Front Face Terminal Block products): When connecting the device, secure Earth connection before connecting L and N. When disconnecting the device, remove L and N connections before removing the Earth connection.

































Functions

Start-up Time

The time required for the output voltage to reach 90% of its final steady state set value, after the input voltage is applied.



Rise Time

The time required for the output voltage to change from 10% to 90% of its final steady state set value.



Hold-up Time

Time between the collapse of the AC input voltage, and the output falling to 95% of its steady state set value.



Graph illustrating the Start-up Time, Rise Time, and Hold-up Time





Inrush Current

Inrush current is the peak, instantaneous, input current measured and, occurs when the input voltage is first applied. For AC input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied AC voltage. This peak value decreases exponentially during subsequent cycles of AC voltage.






Dynamic Response

The power supply output voltage will remains within ± 5% of its steady state value, when subjected to a dynamic load from 0 to 100% of its rated current.

50% duty cycle / 5 Hz to 1 KHz




Overload & Overcurrent Protections (Auto-Recovery)

The power supply’s Overload (OLP) and Overcurrent (OCP) Protections will be activated when output current exceeds 120% of IO (Max load). In such occurrence, the VO will start to droop and once the power supply has reached its maximum power limit, the protection is activated and the power supply will go into “Hiccup mode” (Auto-Recovery). The power supply will recover once the fault condition of the OLP and OCP is removed and IO is back within the specifications.



It is not recommended to prolong the duration of IO when it is <120% but >100%, since it may cause damage to the PSU.



Short Circuit Protection (Auto-Recovery)

The power supply’s output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in “Hiccup mode”, as shown in the illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed.


Overvoltage Protection (Auto-Recovery)

The power supply’s overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 3 under “Protections”.




Over Temperature Protection (Auto-Recovery)

As described in load de-rating section, the power supply also has Over Temperature Protection (OTP). In the event of a higher operating temperature at 100% load, the power supply will run into OTP when the operating temperature is beyond what is recommended in the de-rating graph. When activated, the output voltage will go into bouncing mode until the temperature drops to its normal operating temperature as recommended in the de-rating graph


Others


Attention

Delta provides all information in the datasheets on an “AS IS” basis and does not offer any kind of warranty through the information for using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shall prevail (please refer to www.DeltaPSU.com for the latest datasheets information). Delta shall have no liability of indemnification for any claim or action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for evaluation of using the product before placing an order with Delta.


Delta reserves the right to make changes to the information described in the datasheets without notice.


Manufacturer and Authorized Representatives Information

Manufacturer


Thailand

Delta Electronics (Thailand) PCL.

909 Pattana 1 Rd., Muang, Samutprakarn, 10280 Thailand

Taiwan

Delta Electronics, Inc.

3 Tungyuan Road, Chungli Industrial Zone, Taoyuan County32063, Taiwan



Authorized Representatives


The Netherlands

Delta Greentech (Netherlands) B.V.

Zandsteen 15, 2132 MZ Hoofddorp, The Netherlands


United Kingdom

Delta Electronics Europe Limited

1 Redwood Court, Peel Park Campus,

East Kilbride, Glasgow, G74 5PF, United Kingdom




       Document Revision Record


Date
Item
Content Revised
Page Affected
Rev
12 Dec 16
1

Revised model numbering content

Updated TUV mark

1
03

2
Updated standards;

Added “Safety Entry Low Voltage”.

CE: ”In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
4


3
Change drawing
6-10


4
Updated to align with new DS format

Updated footer

Updated bullets

Output Voltage, Output Current: added “Rated

Output Ratings/Characteristics: added “*” and remark under the table for power de-rating information.

Re-worded “Output Voltage Tolerance “ to “Factory Set Point Tolerance

PARD: added “**” and remark under the table for measurement conditions.

Hold Up Time: added “(100% load)” at 115Vac.

Combine case chassis and cover

Added inch, lb, ft., lbf.in

Revised “EMC / Emissions” to “Emissions (CE & RE)”.

Engineering Data

Re-worded “De-rating” to “Output Load De-rating VS Surrounding Air Temperature”

Re-worded “Output De-rating VS Input Voltage” to “Output Load Derating VS Input Voltage”

Revise “Note” item 5.

Functions: revised Start-up Time, Rise Time, Hold-up Time

Protections

Added “(Auto-Recovery)”

Updated description for “Over Temperature Protection”


All
1
1
2


2
2
2
3
1, 3, 6-13
4
11






14
15





10 Jan 18
1

Update Highlights & Features:

Universal AC input voltage range

Modify Model number from PMT-12V35W1A to PMT-12V35W1☐☐

Modify CC code Blank – Without connector cover

A – With connector cover
B – With conformal coating

Output Current: Add (xxxW max.)

Add Max Power Dissipation

Dynamic Response description : Add (Slew Rate: 0.1A/μS, 50% duty cycle @ 5Hz)

Revised Input Voltage Range : 90-264Vac

Add “Noise (1 meter from power supply)

Environment : Add “Over Voltage Category”

Protections : Add “Internal Fuse at L pin” & “Degree of Protection”

Emission (CE & RE): Replace CISPR22, EN55022 by CISPR32, EN55032

Voltage Dips: Add “and Interruptions”

Engineering Data, revise “Note” item 2.

Assembly & Installation: for PM-12V35W1AH connector

Re-word “Use flexible cable (stranded or solid) of AWG No. 22-18. Please refer to Table 1 for the recommended Housing and Terminal.” to “Please refer the table below for the recommended mating connector, terminal and AWG wire size.”

Re-word “Connector (Board Mounting)” to “Header (Board Mounting)”

Re-word “Housing” to “Mating Connector”

Add column for AWG wire size

Revised Mounting screw length : 6mm


1


1




2
2
2


2
3
3
3
4


11
12






3, 12
12
13
04
11 Nov 18
1
Change dynamic responseAdd attention paragraph
14
15

8 May 20
123
Change drawingRemove RoHS Add connector type image
6~84,151
06
06 Oct 20
1
Add 62368-1
4
07
30 Apr 21
1
- Add UKCA logo
- Change Certificates for Other Countries in Safety Standards section

Add Manufacturer and Authorized Representatives Information

Remove Accessories part

BY Warat
141511
08
28 May 21
1
Add EN/BS after EN 60950-1, EN 62368-1 in safety partAdd EN/BS after EN 55032, EN 55024 in EMC part
4
09
23 Sep 21
1
Add BIS cert logo and detail
1,4
10
24 Feb 22
1
- Remove CCC mark
By Peeraya
1, 4
08
05 July 24
1
Add BIS CCC (only for PMF-12V35W1AA) Revise Engineering data “5. contact form”By Warat
1,48
09




价格
***
订货型号
PMT-12V35W1AA
输入电压
90Vac~264Vac 单相
输出电压
12VDC
输出电流
2.92A
输出功率
35W
外壳材料
熱浸鋅金属上盖
产品认证
CB | CCC | CE| UL | TUV
库存状态
现货
库存量
1000
备注
每箱20台/常備庫存